TitleProduct

AC Resonant Test System

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Hubei

  • Validity to:

    Long-term effective

  • Last update:

    2021-06-10 07:49

  • Browse the number:

    123

Send an inquiries

Company Profile

Wuhan Goldhome Hipot Electrical Co., Ltd

By certification [File Integrity]

Contact:goldhomehipot2020(Mr.)  

Email:

Telephone:

Phone:

Area:Hubei

Address:Hubei

Website:http://www.hvcablehipot.com/ http://goldhomehipot2020.king-wiremesh.com/

PRODUCT DETAILS

AC Resonant Test System 4000kvA/800kV


Product description


HMCXZ AC Resonant Test System is suitable for 10KV, 35KV, 110KV, 220KV, 500KV polyhexene power cable AC withstand voltage test. It is suitable for the AC withstand voltage test of large-capacity equipment such as 60KV, 220KV, 500KV GIS, transformers, insulators, busbars, busbars, and hydroelectric generators.

 

HMCXZ AC Resonant Test System is mainly composed of variable frequency controller, excitation transformer, high voltage reactor, high voltage divider and so on. The frequency conversion controller is divided into two categories, 55KW and above are desktop type, and below 55KW is portable box type; it is composed of a controller and a filter. The main function of the variable frequency controller is to convert the 380V or 220V power frequency sine alternating current with fixed amplitude and frequency into a sine wave with adjustable amplitude and frequency. And provide power for the whole set of equipment. The function of the excitation transformer is to raise the output voltage of the variable frequency power supply to a suitable test voltage. The high voltage reactor L is an important part of the resonant circuit. When the power frequency is equal to 1/(2π√LCX), it will resonate in series with the tested product CX.

 

The AC Resonant Test System is to change the system inductance and test frequency to make circuit in resonant condition. Its electric circuit is shown in Fig.1. The adoption of variable frequency resonant technology reduces the capacity of power source and the weight of equipment, which facilitates on-site test.


Fig.1

Hot tag: series resonance test set,ac dielectric test system supplier,resonance hipot test device,cable withstand voltage test device manufacturer.

 

4000kvA/800kV Variable Frequency Resonant test set applied test object 


Device combine Test object

Reactor: 1000kVA/200kV  4 pcs

Exciting transformeroutput selection

110kV,630mm2,3km power cable

4 pcs in parallel

6kV

220kV,630mm2,1.2km power cable

4pcs,2 in series, 2group in parallel

 12kV

110 kV power system、busbar、GIS,etc

2 pcs in series

12kv

220 kV power system、busbar、GIS,etc

3 pcs in series

12kv

500 kVpower system、busbar、GIS,etc

4 pcs in series

36kv


Test object & Test requirement


1) .500KV and below switche and instrument transformer AC withstand voltage test,test frequency 30-300Hz,test voltage 740kV,test time 1min.

2.220kV/630mm2 0.6km cable  AC withstand voltage test,capacitance≤0.086uF,test frequency 30-300Hz,test voltage 216kV,test time60min.

3.110kV/630mm2 1.5Km cable AC withstand voltage test,capacitance≤0.3uF,test frequency 30-300Hz,test voltage  128kV,test time 60min.


Product main parameter


Item

Configuration

Main parameter

Quantity

1

High voltage reactor

JLB-200kVA/6kV12kV/36kV/0.2kV/0.4kV

1set

2

Variable-frequency power source 

CHXB-F-200kW/0.22/kV/0.38kV

1 set

3

High voltage reactor

DK-1000kVA/200kV

4 sets

4

High voltage reactor

FCR-800kV/750pF

1 set

5

Testing cable


1 set

6

Insulating support


1set

All Specifications can be customized according to client’s requirements.

2.when withstand, Reactor selection Instrunction

1)the above configuration proposal is made according to the longest cable.

2) for short cable or test object with no capacitance,in order to reach to find resonance frequency,usually connect the resonance capacitor with loop in parallel.


4000kvA/800kV Variable Frequency Resonant factory release test picture



Reference date of equivalent capacitances of common testing object of AC resonant test system


C=εΑ/d ,ε---permittivity of medium,Α---electrode area,d---Electrode distance
Appendix 1. List of electricity capacity of several common subjects

Testing object

Capacitance

Power transformer 1-100MVA

1-6MVA:3000-10000pF

10MVA:5000-12000 pF

20MVA:7500-15000 pF

60MVA:13000-20000 pF

100MVA:15000 Pf-20000 pF


300MVA:20000 Pf-30000 pF

CVT

3000-5000 pF

HV circuit breaker、CT、PT

100-1000 pF

Swichgear(common and SF6)

300-1000 pF

 high-pressure pipe

50-600 pF

Insulator

<100 pF

Insulation tool

10-100 pF

overhead conductor and bus(per meter)

8-10 pF

Appendix 2:35KV And 35kV below capacitance of cable

Cross-sectional area of the single conductor (mm²;)

18/20KV

6/6KV
6/10KV

8.7/10KV
8.7/15KV

26/35KV

μF/KM

μF/KM

μF/KM

μF/KM

25

0.1163

0.1922

0.1567

0.0992

35

0.1251

0.2116

0.1725

0.1061

50

0.1362

0.2357

0.1917

0.1150

70

0.1508

0.2693

0.2167

0.1263

95

0.1643

0.2999

0.2400

0.1368

120

0.1760

0.3266

0.2603

0.1460

150

0.1893

0.3570

0.2834

0.1563

185

0.2026

0.3873

0.3123

0.1665

240

0.2207

0.4296

0.3439

0.1805

300

0.2387

0.4706

0.3755

0.1945

400

0.2648

0.5311

0.4213

0.2146

500

0.2876

0.5839

0.4613

0.2321

630

0.3151

0.6481

0.5099

0.2533

Appendix 3:110KV、220KV capacitance of cable

110KV

220KV

Cross-sectional area of the single conductor(mm²;)

Capacitance(μF/KM)

Cross-sectional area of the single conductor(mm²;)

Capacitance(μF/KM)

240

0.136

240

0.110

300

0.147

300

0.117

400

0.165

400

0.125

500

0.182

500

0.134

630

0.201

630

0.144

800

0.224

800

0.155

1000

0.265

1000

0.180

1200

0.282

1200

0.190



1400

0.198



1600

0.204



1800

0.212



2000

0.222


attention

prevent fire or personal injury!

Use appropriate power cord: can only use this product special, and conform to the product specifications of the power cord.

Properly connect and disconnect: when tests conductors and charged terminal connections, not optional connect or disconnect test wires.

Product grounding: this product except through the power grounding wires grounding,shell grounding column must be grounded. In order to prevent the shock, grounding must be connected with the ground conductor. With this product in the input or output terminal connections and shall ensure the product before already correct grounded.

Note that all terminal's rated value: in order to prevent fire or shock, please note all the rated value and mark of the product. please read this product before operation instruction, in order to further understand the information about rated value.

Don't operate without instruments cover plat ,such as already unloaded plat or panel, please do not operate this product.

In a suspicious fault, not operation: such as suspect this product has damaged, please contact the company maintenance personnel for inspection, do not continue to operate.



FAQ


1.Can you provide the training for us?

Yes, we can provide free training for our client at our factory.

If you require the training on-site, we also can arrange accordingly.

We have 10 seasoned engineers who become our technical team, they flied many countries for client’s installation and commissioning!

2.What is your after-sale service

We have 10 seasoned technical engineer as the after-sale service team.it is lead by our duty manager. We promise that our engineer can give answers within 1 hour and deal with equipment failure within 24 hours in time.

3.What’s the warranty period ?

Our warranty period is one year .

The product can be replaced within 1 month, can be repaired for free charge  for one year and maintenance for lifetime.

What is more, our warranty can be extended only charged small warranty fee.

http://www.hvcablehipot.com/