AC Resonant Test System 4000kvA/800kV
Product description |
HMCXZ AC Resonant Test System is suitable for 10KV, 35KV, 110KV, 220KV, 500KV polyhexene power cable AC withstand voltage test. It is suitable for the AC withstand voltage test of large-capacity equipment such as 60KV, 220KV, 500KV GIS, transformers, insulators, busbars, busbars, and hydroelectric generators.
HMCXZ AC Resonant Test System is mainly composed of variable frequency controller, excitation transformer, high voltage reactor, high voltage divider and so on. The frequency conversion controller is divided into two categories, 55KW and above are desktop type, and below 55KW is portable box type; it is composed of a controller and a filter. The main function of the variable frequency controller is to convert the 380V or 220V power frequency sine alternating current with fixed amplitude and frequency into a sine wave with adjustable amplitude and frequency. And provide power for the whole set of equipment. The function of the excitation transformer is to raise the output voltage of the variable frequency power supply to a suitable test voltage. The high voltage reactor L is an important part of the resonant circuit. When the power frequency is equal to 1/(2π√LCX), it will resonate in series with the tested product CX.
The AC Resonant Test System is to change the system inductance and test frequency to make circuit in resonant condition. Its electric circuit is shown in Fig.1. The adoption of variable frequency resonant technology reduces the capacity of power source and the weight of equipment, which facilitates on-site test.
Fig.1
Hot tag: series resonance test set,ac dielectric test system supplier,resonance hipot test device,cable withstand voltage test device manufacturer.
4000kvA/800kV Variable Frequency Resonant test set applied test object |
Device combine Test object |
Reactor: 1000kVA/200kV 4 pcs |
Exciting transformeroutput selection |
110kV,630mm2,3km power cable |
4 pcs in parallel |
6kV |
220kV,630mm2,1.2km power cable |
4pcs,2 in series, 2group in parallel |
12kV |
110 kV power system、busbar、GIS,etc |
2 pcs in series |
12kv |
220 kV power system、busbar、GIS,etc |
3 pcs in series |
12kv |
500 kVpower system、busbar、GIS,etc |
4 pcs in series |
36kv |
Test object & Test requirement |
1) .500KV and below switche and instrument transformer AC withstand voltage test,test frequency 30-300Hz,test voltage 740kV,test time 1min.
2.220kV/630mm2 0.6km cable AC withstand voltage test,capacitance≤0.086uF,test frequency 30-300Hz,test voltage 216kV,test time60min.
3.110kV/630mm2 1.5Km cable AC withstand voltage test,capacitance≤0.3uF,test frequency 30-300Hz,test voltage 128kV,test time 60min.
Product main parameter |
Item |
Configuration |
Main parameter |
Quantity |
1 |
High voltage reactor |
JLB-200kVA/6kV12kV/36kV/0.2kV/0.4kV |
1set |
2 |
Variable-frequency power source |
CHXB-F-200kW/0.22/kV/0.38kV |
1 set |
3 |
High voltage reactor |
DK-1000kVA/200kV |
4 sets |
4 |
High voltage reactor |
FCR-800kV/750pF |
1 set |
5 |
Testing cable |
1 set |
|
6 |
Insulating support |
1set |
All Specifications can be customized according to client’s requirements.
2.when withstand, Reactor selection Instrunction
1)the above configuration proposal is made according to the longest cable.
2) for short cable or test object with no capacitance,in order to reach to find resonance frequency,usually connect the resonance capacitor with loop in parallel.
4000kvA/800kV Variable Frequency Resonant factory release test picture |
Reference date of equivalent capacitances of common testing object of AC resonant test system |
C=εΑ/d ,ε---permittivity of medium,Α---electrode area,d---Electrode distance
Appendix 1. List of electricity capacity of several common subjects
Testing object | Capacitance |
Power transformer 1-100MVA |
1-6MVA:3000-10000pF |
10MVA:5000-12000 pF | |
20MVA:7500-15000 pF | |
60MVA:13000-20000 pF | |
100MVA:15000 Pf-20000 pF | |
300MVA:20000 Pf-30000 pF |
|
CVT |
3000-5000 pF |
HV circuit breaker、CT、PT |
100-1000 pF |
Swichgear(common and SF6) |
300-1000 pF |
high-pressure pipe |
50-600 pF |
Insulator |
<100 pF |
Insulation tool |
10-100 pF |
overhead conductor and bus(per meter) |
8-10 pF |
Appendix 2:35KV And 35kV below capacitance of cable
Cross-sectional area of the single conductor (mm²;) | 18/20KV |
6/6KV |
8.7/10KV |
26/35KV |
μF/KM |
μF/KM |
μF/KM |
μF/KM |
|
25 |
0.1163 |
0.1922 |
0.1567 |
0.0992 |
35 |
0.1251 |
0.2116 |
0.1725 |
0.1061 |
50 |
0.1362 |
0.2357 |
0.1917 |
0.1150 |
70 |
0.1508 |
0.2693 |
0.2167 |
0.1263 |
95 |
0.1643 |
0.2999 |
0.2400 |
0.1368 |
120 |
0.1760 |
0.3266 |
0.2603 |
0.1460 |
150 |
0.1893 |
0.3570 |
0.2834 |
0.1563 |
185 |
0.2026 |
0.3873 |
0.3123 |
0.1665 |
240 |
0.2207 |
0.4296 |
0.3439 |
0.1805 |
300 |
0.2387 |
0.4706 |
0.3755 |
0.1945 |
400 |
0.2648 |
0.5311 |
0.4213 |
0.2146 |
500 |
0.2876 |
0.5839 |
0.4613 |
0.2321 |
630 |
0.3151 |
0.6481 |
0.5099 |
0.2533 |
Appendix 3:110KV、220KV capacitance of cable
110KV |
220KV |
||
Cross-sectional area of the single conductor(mm²;) |
Capacitance(μF/KM) |
Cross-sectional area of the single conductor(mm²;) |
Capacitance(μF/KM) |
240 |
0.136 |
240 |
0.110 |
300 |
0.147 |
300 |
0.117 |
400 |
0.165 |
400 |
0.125 |
500 |
0.182 |
500 |
0.134 |
630 |
0.201 |
630 |
0.144 |
800 |
0.224 |
800 |
0.155 |
1000 |
0.265 |
1000 |
0.180 |
1200 |
0.282 |
1200 |
0.190 |
1400 |
0.198 |
||
1600 |
0.204 |
||
1800 |
0.212 |
||
2000 |
0.222 |
attention
prevent fire or personal injury!
Use appropriate power cord: can only use this product special, and conform to the product specifications of the power cord.
Properly connect and disconnect: when tests conductors and charged terminal connections, not optional connect or disconnect test wires.
Product grounding: this product except through the power grounding wires grounding,shell grounding column must be grounded. In order to prevent the shock, grounding must be connected with the ground conductor. With this product in the input or output terminal connections and shall ensure the product before already correct grounded.
Note that all terminal's rated value: in order to prevent fire or shock, please note all the rated value and mark of the product. please read this product before operation instruction, in order to further understand the information about rated value.
Don't operate without instruments cover plat ,such as already unloaded plat or panel, please do not operate this product.
In a suspicious fault, not operation: such as suspect this product has damaged, please contact the company maintenance personnel for inspection, do not continue to operate.
FAQ |
1.Can you provide the training for us?
Yes, we can provide free training for our client at our factory.
If you require the training on-site, we also can arrange accordingly.
We have 10 seasoned engineers who become our technical team, they flied many countries for client’s installation and commissioning!
2.What is your after-sale service
We have 10 seasoned technical engineer as the after-sale service team.it is lead by our duty manager. We promise that our engineer can give answers within 1 hour and deal with equipment failure within 24 hours in time.
3.What’s the warranty period ?
Our warranty period is one year .
The product can be replaced within 1 month, can be repaired for free charge for one year and maintenance for lifetime.
What is more, our warranty can be extended only charged small warranty fee.
http://www.hvcablehipot.com/
Digital Pathology Slide Scanner
price:Negotiable
Belt Conveyor Rubber
price:Negotiable
97-74-5 Rubber Accelerator TMTM(TS) Bis(dimethylthiocarbamyl) Sulfide C6H12N2S3
price:Negotiable
Threadbar Rock Bolt
price:Negotiable
Unidirectional Carbon Fiber Wrap
price:Negotiable
971-15-3 Dipentamethylenethiuram Hexasulfide Rubber Accelerator DPTT (DPTH) C12H20N2S8
price:Negotiable